Ao-smith BFC - 28 User Manual Page 77

  • Download
  • Add to my manuals
  • Print
  • Page
    / 96
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 76
is
Release R.1.3 UK 77
Warning
Maintenance may only be performed by a qualified service and maintenance engineer.
F04 (lock out error)
Three unsuccessful
ignition attempts.
No gas. 1. Open the main gas valve and/or the gas valve before the gas
control.
2. Check supply pressure to the gas control.
3. If necessary, repair the gas supply.
To repair the gas supply, contact your installer.
Air in the gas pipes. Bleed the air out of the gas pipe. See ’3.11 Checking the supply pressure and burner pressure’ for
how to bleed air from the gas line, and measure the supply
pressure and burner pressure.
To replace the necessary parts, you must contact your installer.
No burner pressure. 1. Check the burner pressure at the gas control.
2. Check that the gas valve(s) open and shut correctly.
3. If necessary, replace the gas control.
Defect in the glow
igniter circuit.
1. Check that the glow igniter is correctly connected (JP2).
2. Check the wiring of the glow igniter.
3. Measure the resistance across the glow igniter. This must lie
between 2 and 5 .
4. Check that the glow igniter lights up during ignition.
5. If necessary, replace the glow igniter.
If the error persists, contact your installer.
To replace the necessary parts, you must contact your installer.
Defect in the ionisation
circuit.
1. Check that the ionisation rod is correctly connected (JP2).
2. Check the wiring of the ionisation rod.
3. Measure the ionisation current. This must be a minimum of 1.5
µA.
4. If necessary, replace the wiring.
Supply voltage too low Check the supply voltage to the appliance. This must be 230 VAC
(+10% -15%).
Table 10.2 Displayed errors (Sheet 5 of 10)
Code + Description Possible cause Solution Remark